| Tolerances for bars and mesh not used as a fitment | |
|---|---|
| ≤ 600mm | -25, ±0 |
| > 600mm | -40, ±0 |
| Tolerances for bars and mesh used as a fitment | |
|---|---|
| Deformed Bars and Mesh | -15, ±0 |
| Plain Round Bars and Wire | -10, ±0 |
| Ovearll dimension of a cranked column bar | -0+10 |
| For the sawn or machined end of a straight bar intended for use as an end-bearing splice, the angular deviation from square, measured in relation to the end 300 mm, shall be within | 2º |
Source
AS/NZS Standards documentation
Related Link: SRIA